Infrared Space Heaters  |
| Model # |
Gas Type |
Heat Control |
No. of Plaques |
BTU Output |
Heating Area (Sq. Ft.) |
Floor Stand |
Blower
(Optional) |
Dimensions HxWxD |
| KWN109 |
Nat |
Variable |
1 |
6,000 |
200 |
20-5243 |
N/A |
19.1 x 14.1 x 6.4 |
| KWP110 |
LP |
Variable |
1 |
6,000 |
200 |
20-5243 |
N/A |
19.1 x 14.1 x 6.4 |
| KWN111 |
Nat |
Variable |
2 |
10,000 |
300 |
20-5243 |
N/A |
18.9 x 14.2 x 5.7 |
| KWP112 |
LP |
Variable |
2 |
10,000 |
300 |
20-5243 |
N/A |
18.9 x 14.2 x 5.7 |
| KWN121 |
Nat |
T-Stat |
2 |
10,000 |
300 |
20-5243 |
N/A |
18.9 x 14.2 x 5.7 |
| KWP122 |
LP |
T-Stat |
2 |
10,000 |
300 |
20-5243 |
N/A |
18.9 x 14.2 x 5.7 |
| KWN191 |
Nat |
Variable |
3 |
18,000 |
600 |
20-5242 |
20-6027 |
23.0 x 19.0 x 7.0 |
| KWP192 |
LP |
Variable |
3 |
15,000 |
600 |
20-5242 |
20-6027 |
23.0 x 19.0 x 7.0 |
| KWN195 |
Nat |
T-Stat |
3 |
18,000 |
600 |
20-5242 |
20-6027 |
23.0 x 19.0 x 7.0 |
| KWP196 |
LP |
T-Stat |
3 |
15,000 |
600 |
20-5242 |
20-6027 |
23.0 x 19.0 x 7.0 |
| KWN321 |
Nat |
Variable |
5 |
30,000 |
1000 |
20-5242 |
20-6027 |
23.0 x 26.6 x 7.0 |
| KWP322 |
LP |
Variable |
5 |
25,000 |
1000 |
20-5242 |
20-6027 |
23.0 x 26.6 x 7.0 |
| KWN323 |
Nat |
T-Stat |
5 |
30,000 |
1000 |
20-5242 |
20-6027 |
23.0 x 26.6 x 7.0 |
| KWP324 |
LP |
T-Stat |
5 |
25,000 |
1000 |
20-5242 |
20-6027 |
23.0 x 26.6 x 7.0 |
- Products cannot be converted between gases. Not for use with any well-head gas.
- Heating areas are estimates based on 8 ft ceilings. Actual heating needs may vary based on conditions of use, insulation, and other local factors.
- Due to ongoing product development specifications are subject to change without notice.
- Bathroom installations limited to 6,000 BTU's, Bedrooms should be limited to 10,000 BTU's.
- Not recommended for use in elevations above 5,000 feet.
Blue Flame Space Heaters 
|
| Model # |
Gas Type |
Heat Control |
Burner Size |
BTU Output |
Heating Area (Sq. Ft.) |
Floor Stand |
Blower
(Optional) |
Dimensions HxWxD |
| KWN113 |
Nat |
Variable |
10" |
10,000 |
300 |
20-5243 |
N/A |
18.9 X 14.2 X 5.7 |
| KWP114 |
LP |
Variable |
10" |
10,000 |
300 |
20-5243 |
N/A |
18.9 X 14.2 X 5.7 |
| KWN217 |
Nat |
T-Stat |
10" |
20,000 |
700 |
20-5242 |
20-6027 |
23.0 X 19.0 X 7.0 |
| KWP218 |
LP |
T-Stat |
10" |
20,000 |
700 |
20-5242 |
20-6027 |
23.0 X 19.0 X 7.0 |
| KWN317 |
Nat |
T-Stat |
17" |
30,000 |
1000 |
20-5242 |
20-6027 |
23.0 X 19.0 X 7.0 |
| KWP318 |
LP |
T-Stat |
17" |
30,000 |
1000 |
20-5242 |
20-6027 |
23.0 X 19.0 X 7.0 |
- Products cannot be converted between gases. Not for use with any well-head gas.
- Heating areas are estimates based on 8 ft ceilings. Actual heating needs may vary based on conditions of use, insulation, and other local factors.
- Due to ongoing product development specifications are subject to change without notice.
- Bathroom installations limited to 6,000 BTU's, Bedrooms should be limited to 10,000 BTU's.
- Not recommended for use in elevations above 5,000 feet.


|
|
|
|
 |